...PegaSync provides 24/7/365 Monitoring Service.... Rain or Shine....... Free Quote.... PegaSync's MI License No.: 3601207197 ..... Residential Monitoring Plans at PegaSync..PegaSync provides 24/7/365 Monitoring Service.... Rain or Shine....Current Job Openings at PegaSync .....PegaSync provides 24/7/365 Monitoring Service.... Rain or Shine....Opportunities for subcontractors at PegaSync...PegaSync provides 24/7/365 Monitoring Service.... Rain or Shine.... Call 248-341-9580 for Free Quote .... PegaSync's MI License No.:  3601207197 ....  Current Job Openings at PegaSync...PegaSync provides 24/7/365 Monitoring Service.... Rain or Shine.......Residential Monitoring Plans at PegaSync ...PegaSync provides 24/7/365 Monitoring Service.... Rain or Shine.......Opportunities for subcontractors at PegaSync

Switch your security system to PegaSync & save up to $ 1460 in equipment cost plus peace of mind
Free Installation and Free expert Consultation by Pegasync Team of Security Systems Professionals

Surge Protectors - Few Important Points

Surge Protectors : Are You Protected?  Can you Count On it?

The protection provided by a surge protector on your system and its devices is essential, as surge events are unpredictable and can damage or even destroy electrical equipment essential to your system’s operation. However, there are several common problems that may occur during the installation of a surge protection device (SPD) that will prevent it from giving you the protection you need. There are ways to ensure that you are getting the proper surge protection from your SPD,  after you have installed it on your system.

Surge Protectors with Visual Indicators.

While many SPDs are designed with no easy fully functional visual indicator, SPDs from leading manufacturers often provide a visual indication when replacement of SPD is required. The downside is that normally you have to make a physical inspection to see this indication. The most common indicator is one or more LED lights installed for this purpose; when lit, they confirm normal operation and protection. A low-voltage surge protector will either short to ground or open the circuit, depending on the specific design of the device, when it has done its job and sacrificed itself to protect your equipment. When that happens, the LED indicator light will turn off, signaling that the SPD requires replacement. Ensure that you have installed your surge protector correctly and quickly replace it when one or more damaging surge event has worn the device out.

Proper Grounding.

While there are a myriad of common installation errors that can prevent proper surge protection from occurring, improper grounding is the root of most installation issues with SPDs.

In order to ensure that the surge protection device has time to react and dissipate the charge, the absolute minimum wire distance on which a surge protector should be placed is 3 feet ( 1 meter ). A longer wire distance will give the device more time to perform the dissipation. Often a device is installed in the most convenient location near the equipment it is protecting, and the lead length is not long enough to allow the device to perform properly. Ensure that your device is installed with a proper lead.

For example, if you are installing your surge protector on an IP camera mounted on a high pole, it is not best practice to put your surge protection device up near the location of the camera. Placing the device at the base of the pole gives the proper lead length to dissipate the charge, and a shorter distance to the ground in order to send the charge elsewhere. Though it may seem like your surge protector will protect your video cameras better if it is nearby, a well-grounded device with proper lead length is a protector that is able to function properly.

Avoid Installation Shortcuts.

Installation shortcuts can impede the functionality of your surge protector. Chaining multiple ground wires together or adding twist-on wire-connectors, or ‘wire nuts’, can add resistance and impedance to the grounding path. Wire nuts, additionally, may become loose or corroded over time, and can increase the resistance of the grounding conductor unnecessarily. Ensure that your surge protection is installed with a grounding bus bar to terminate ground wires to existing leads.

IEEE and Manufacturer's Standards.

Installation issues are not the only possibility for the cause of improper surge protection on your critical equipment. Manufacturer standards are often a great resource to corroborate that you are installing the surge protection your equipment requires, and that the surge protection is being installed using best practices. The Institute of Electrical and Electronics Engineers (IEEE), has a ‘trilogy’ of standards that can provide installation guidelines for location, level of exposure, and voltage. By comparing with the manufacturer’s standards for surge protection, you can ensure that the protection you install on your critical systems is specific to the devices you need to protect.

For additional information on safe practices for Surge Protectors usage and installation,  please click the button below to contact PegaSync Alarm Inc.